Use case for reading a location resource

Prerequisites

Consumer

The consumer system:

API use case

This page describes a single use case. For complete details and background please see the Foundations Capability Bundle.

Security

  • GP Connect utilises TLS Mutual Authentication for system level authorization.
  • GP Connect utilises a JSON Web Tokens (JWT) to transmit clinical audit & provenance details.

API usage

Request operation

FHIR relative request

GET /Location/[id]

FHIR absolute request

GET https://[proxy_server]/https://[provider_server]/[fhir_base]/Location/[id]

Request headers

Consumers SHALL include the following additional HTTP request headers:

Header Value
Ssp-TraceID Consumer’s TraceID (i.e. GUID/UUID)
Ssp-From Consumer’s ASID
Ssp-To Provider’s ASID
Ssp-InteractionID urn:nhs:names:services:gpconnect:fhir:rest:read:location-1

Payload request body

N/A

Error handling

Provider systems SHALL return a GPConnect-OperationOutcome-1 resource that provides additional detail when one or more data fields are corrupt or a specific business rule/constraint is breached.

For example, the:

  • Logical identifier of the resource is not valid/can’t be found on the server.

Refer to Development - FHIR API Guidance - Error Handling for details of error codes.

Request response

Response headers

Provider systems are not expected to add any specific headers beyond that described in the HTTP and FHIR® standards.

Payload response body

Provider systems:

  • SHALL return a 200 OK HTTP status code on successful execution of the operation.
  • SHALL return Location resources that conform to the CareConnect-GPC-Location-1 profile.

  • SHALL populate the following Location fields:
    • meta.profile with the profile URI
    • versionId with the current version of each Location resource.
    • name
    • address where available
    • telecom where available
    • managingOrganization with a reference to the ‘managing’ organisation. For Locations that are managed by GP practices, see Branch surgeries for more details.
  • SHALL meet General FHIR resource population requirements populating all fields where data is available, excluding those listed below

  • SHALL NOT populate the following fields:
    • endpoint
{
  "resourceType": "Location",
  "id": "17",
  "meta": {
    "versionId": "636064088100870233",
    "profile": [
      "https://fhir.nhs.uk/STU3/StructureDefinition/CareConnect-GPC-Location-1"
    ]
  },
  "name": "Trevelyan Surgery",
  "address": [
    {
      "line": [
        "Trevelyan Square",
        "Boar Ln"
      ],
      "city": "Leeds",
      "district": "West Yorkshire",
      "postalCode": "LS1 6AE"
    }
  ],
  "telecom": [
    {
      "system": "phone",
      "value": "03003035678",
      "use": "work"
    }
  ],
  "managingOrganization": {
    "reference": "Organization/14"
  }
}